Maintenance of an autonomous water supply system includes control over pumping equipment and serviceability of communications, conservation of the network during a long absence, rational automatic control.
Automation is easy to implement by installing a pump control cabinet in a designated location, a compact distribution station that operates in several modes. We will tell you in detail how to correctly assemble and install it. Following our tips, you can correctly connect the equipment.
We have given a standard complete set of a control cabinet. We described what additional functions can be installed and used. The information proposed for consideration was supplemented by useful illustrations and videos.
Appointment and complete set of SHUN
The technical filling of different models is different, since the control points have an individual functional orientation.
Manufacturers offer ready-made standard schemes, but they do not always meet specific requirements, so there is a service such as custom-made control unit manufacturing. To begin with, we will try to consider common positions that unite all models.
Functional responsibilities of the control cabinet
The main function of any distribution station is to organize the operation of equipment connected to it, in this case, pumping equipment. From one control panel (and this is convenient if the distance between the objects is large), control over the motors of drainage, surface, and borehole pumps is effectively carried out.
The number of connected units may vary. The minimum connection is one borehole or submersible pump, which delivers water and provides it with the presence of the entire water supply system (heating, fire fighting). In addition to it, a drainage pump is connected, which is necessary for pumping water in domestic and emergency situations.
Image Gallery
Photo from
The functional purpose of the pump control cabinets is to protect the pumping equipment and control the performance by changing the frequency of the load
In addition to standard automatic devices that protect electrical equipment from overloads and prevent operation in an out-of-phase mode, the cabinets are equipped with sensors that respond to violation of pump operating modes
Among the devices that are important for the normal operation of the device are sensors that record and signal the absence of voltage in the network, the water level falls below a limited limit, maturing or occurrence of accidents
The most common Shun group controls all types of water pumps that provide water intake from a source, supply it to consumers, increase pressure
Cabinet for monitoring the operation of circulating pumps that provide continuous movement of the coolant in the heating circuit or increase the pressure in the water supply
A cabinet for monitoring the operation and control of sewage pumping systems requires, if necessary, moving the drains to the sewer riser under pressure
The drainage control cabinet in a private household is used only if a pump of this type draws water from an open reservoir or well
The layout of the stations can be standard, including a frequency converter, programmable controller, operator panel, etc. You can order its assembly for specific tasks
Shun in the interior of a private house
Typical technical equipment
Alarm indication of a malfunction
Water Pump Management
Circulation pump control cabinet
Sewage pump control station
Drain Pump Management System
Design and layout options for the control station
Automatic on / off pumping engines makes life easier for owners of a private home, allowing them to spend free time with their families, rather than manually switching toggle switches.
A few more convenient functions that can be "entrusted" to automation:
- monitoring the voltage in the network necessary for the smooth operation of the equipment;
- protection of mechanisms from power outages and short circuits;
- monitoring the water level in the well (or other reservoir) and responding to its lack;
- fixation of pressure surges and adjustment of optimal parameters (engine stop when a critical level is reached, start when parameters are equalized);
- remote control of borehole pumps, direct access to which is impossible;
- load distribution between several units or emergency connection of a fallback.
As a result of centralized automatic control, the operation of pumping stations becomes more productive, and the service life of electrical equipment increases markedly. Modern electronic systems allow you to program mechanisms and turn them on in a convenient mode (for example, only in the daytime).
An image of the case and a diagram of the control cabinet with start-up protective equipment and a board for automatically restarting the backup load without specifying a specific modification (+)
All failures are recorded, and an alarm is triggered during an emergency. On the material side - saving energy costs and, accordingly, reducing electricity charges.
An example of a block diagram of the automation of a pumping station with two connected pumps (380 V), which uses a frequency-controlled electric drive (+)
Short description of standard equipment
The presence of certain elements depends on the number and category of pumps, narrow or wider technical capabilities, the availability of additional functions.
Pump control Pressure 3.3: functional diagram of the device. It automatically shuts down and fixes an emergency when overloading, “dry running”, changing the water level in the tank (+)
The basic configuration for most of the models for sale is as follows:
- A rectangular metal housing with a control panel located on the front side. The design of the panel may vary, but there must be indicators and buttons such as "Start" or "Stop" on it.
- A switch (one or more) that allows you to turn on / off the pump in manual mode.
- Fuses and protection elements.
- A control unit that controls the voltage of three phases.
- Frequency converter needed to control an induction motor.
- Automatic adjustment unit responsible for scheduled and emergency shutdown of equipment.
- A set of sensors showing the pressure and temperature of the water.
- Thermal relay.
- A set of bulbs - light alarm.
The main functions incorporated in the control unit depend on several factors. For example, if there are 2 pumps, the main and the secondary (backup), a program is installed that allows you to turn on both mechanisms in turn.
Control panel for two pumps operating in standby mode. The advantage of interval switching is a uniform load distribution and an increase in the planned resource
The temperature sensor protects the equipment from overheating and working in dry running mode (the likelihood of a similar situation occurs often in wells with insufficient flow rate). Automation stops the operation of the equipment, and when favorable conditions for water intake occur, it again turns on the engine of the connected pump.
Image Gallery
Photo from
Equipment management station
Appearance of a standard SHUN
Standard set of security systems
Devices for protection against power surges, phase failure, incorrect connection protect mechanisms and do not allow them to work in emergency mode. They adjust the network parameters, and only after leveling the indicators automatically connect the equipment.
The overload protection functions in approximately the same way. For example, there is a ban on the simultaneous activation of two pumps, which leads to unnecessary costs and wasteful use of equipment.
Almost all debugged systems have the ability to switch from fully automated control to manual. This is necessary for maintenance, repair, replacement of worn or burnt parts
Suppose if one pump fails, it can be removed without hindrance and sent for repair by turning off the automation and using manual control.
Additional options and features
Various manufacturers include additional features in the core kit that expand management capabilities. For example, Alta Group offers an ABP system - turning on backup power in automatic mode. The need for this function is explained by the fact that the work of the pumping station is part of the life support system of the house, therefore, the network must operate in a constant mode.
The principle of operation of the ATS is as follows: as soon as the main power supply stops, the backup network is automatically introduced. It is valid until the main source resumes operation.
When it is turned on, the intelligent system checks the optimality of the parameters, and only with a positive response does it reconnect the main network. If the test analysis is unsatisfactory, the system will continue to operate from the backup source.
Low temperatures and high humidity are the enemies of the electronic filling of the cabinet, so manufacturers offer the service of additional insulation. It is relevant for the northern regions and for any areas if the equipment is on the street.
The so-called "warm package" is a layer of insulation laid on the inside. Heat-insulated SHUNs are operated at a fairly wide temperature range - from -40ºС to +55 ºС
A fairly common addition to protect pump motors from overload is the soft start system. It consists in a neat, gradually increasing voltage supply mode, thanks to which the engine is protected from a sharp start, is put into operation slowly and carefully.
The modern dispatch function allows you to control pumping stations at a distance. Remote warning systems are constantly connected to GPRS, a radio modem or the Internet, due to which, in an emergency, the blocking system immediately turns on and the signal is transmitted to the receiving device (phone or laptop).
A convenient option that allows you to set a specific program is possible thanks to the use of the controller. It is automatically able to independently affect the operation of the pumps, connect additional devices, optimize the functioning of the system as a whole.
Indication implies the location on the cabinet lid of an electronic display with voltage and current indications, as well as statistical data: the number of starts, engine operating hours, water volume
Another good option that allows you to get information about a system shutdown or emergency occurrence is the installation of a light alarm and a siren. When force majeure occurs, the flashing beacon lights up in bright light, and a special sound device emits a loud repeating signal.
Samples of electronic technical wiring diagrams
The equipment is assembled in a production environment, in the same place are drawn up circuit diagrams of the pump control cabinet. The simplest are the connection schemes for one pump, although a set of additional devices can complicate the installation.
Take SUN-0.18-15 (the company Rubezh) as a sample, designed for manual and automatic control of electric drives of a pumping station. The control scheme is as follows:
On the cover of the case there are on / off buttons, a toggle switch, which is responsible for choosing the operating mode, a set of indicators signaling the health of the system (+)
The manufacturer implements 19 basic versions, which differ in the power of the pump station electric motor - from 0.18 kW to 55-110 kW.
Inside the metal case are the following elements:
- automatic switch;
- protection relay;
- contactor;
- backup power source;
- controller.
A cable with a cross section of 0.35-0.4 mm² is required for connection.
A sample of connecting the model SHUN-0.18-15 (for a drainage or fire pump) from the manufacturer Boundary with one drive and a controller that regulates the operation of the equipment (+)
Shunts Grantor, designed for drainage work, control asynchronous motors and have two control options: manual and automatic. Manual adjustment is made from the front panel of the case, the automatic one operates from external relay signals (electrode or float).
Triple diagram depicting the operation of the cabinet on 1, 2 and 3 pumps with float control. If there are 2 or more pumps, load balancing between working and standby equipment
The principle of operation of the SHUN in automatic mode: with a critical decrease in the water level in the water well and the activation of float No. 1, the operation of all pumps stops. In the normal state of the liquid level, float No. 2 fires and one of the pumps starts. When other floats at higher levels are triggered, the remaining units are introduced.
Features of the installation of monitoring stations
Without exception, all versions of SHUN are complex devices that operate on an electrical network, which means that it is necessary to install, commission, maintain and repair equipment according to the manufacturer's instructions. The rules set forth in the instructions of various models may vary, since the design of the mechanisms and technical characteristics are also different.
The electrical connection diagram of the control cabinet for pumping equipment ARIES SHUN 1. Thanks to the use of proprietary frequency converters ARIES, energy savings reach 35%
A few general important rules:
- Installation is carried out in a zone protected from explosions.
- The temperature and humidity in the room must comply with the parameters specified by the manufacturer (for example, temperature from 0ºС to + 30ºС).
- Electrical equipment must be connected by a person with special approval.
- ShUN parameters must match the parameters of all connected equipment.
- Installation is carried out in accordance with the circuit diagrams given in the appendix to the instructions.
- The cable cross-section must match the data indicated in the instructions.
Household control stations located in the private sector are subject to the same requirements as production control points. They must be installed in a dry and warm place, convenient for maintenance. This can be a ground floor, a specially designated room, an extension to the house or a secure utility room.
Unlike large industrial cabinets, household models are compact and lightweight, so most often they are available in wall-mounted design
The connection should be made after the water supply system is fully installed, the pressure pipe is connected, cables are laid, nodes are assembled, all electrical elements are insulated.Having connected the SHUN, it is necessary to check its operation in both manual and automatic mode.
Technical support and service
Some control cabinet companies claim maintenance is not required. This is true, but regular monitoring of the control unit by the operating organization is necessary. There is a frequency established by the manufacturer, and for the proper operation of all devices it must be followed without fail.
Before inspecting or replacing any parts, disconnect the voltage and block the equipment from being switched on again. You can independently verify the reliability of the connections. The list of potential malfunctions, as well as possible solutions to them, is usually also indicated by the manufacturer.
Control cabinet for a borehole or submersible pump with a frequency converter for use in industrial boiler rooms, public utilities or private homes, custom-made according to individual technical specifications
For example, a simple malfunction - a light does not light up, signaling that the system is connected to an electric cable. Three reasons are possible: there is no voltage in the network, the circuit breaker has broken or the lamp has blown. Accordingly, the solution to the problem is to supply voltage, replace the switch or lamp.
If there is a malfunction that cannot be resolved independently, it is necessary to contact a service center.
A brief overview of popular models
Although it is possible to manufacture custom-made SHUNs, many companies offer basic models. Their assembly is carried out, focusing on consumer demand. We offer a brief description of cabinets that can be purchased or ordered on the official websites of companies or in online stores.
SHUN Grundfos Control MP204
Grundfos Control MP204 control cabinets are designed for automatic operation and protection of one pump.
Parameters in the Grundfos Control MP204 can be configured in manual and automatic mode, and there are two threshold values: the first is a warning, the second is an emergency shutdown. A trip log listing the reasons for the response is stored in memory
Specifications:
- Voltage - 380 V, 50 Hz
- Engine power of connected equipment - from 1.1 to 110 kW
- Temperature range - from -30 ° С to +40 ° С
- Degree of protection: IP54
The advantage is the ability to transmit CIU data and adjust parameters via Grundfos GO.
SUN from NPO STOIK
Stations of control of pump units (SUN) from the NPO STOIK company. Designed for automatic control of submersible water intake and drainage pumps, capable of serving from 1 to 8 connections.
Sample 30 kW SUN in a metal hinged enclosure with Aucom soft starter and Delta frequency converter
Specifications:
- Voltage - 380 V, 50 Hz
- Engine power of connected equipment - from 0.75 to 220 kW
- Temperature range - from -10 ° С to +35 ° С
- Degree of protection: IP54
Among the basic functions is the automatic inclusion of ventilation if the temperature inside the cabinet rises above normal.
Cases from the brand Grantor
Grantor multifunctional cabinets are designed for servicing circulating and drainage systems.
Possible operating modes: circulation and drainage by an analog sensor or by a pressure switch. Two options for the operation algorithm involve the joint or alternate activation of pumps
Specifications:
- Voltage - 1x220 V or 3x380 V, 50 Hz
- Engine power of connected equipment - up to 7.5 kW per engine
- Temperature range - from 0 ° С to +40 ° С
- Degree of protection: IP65
In the event of an emergency and a breakdown of the pump motor (due to a short circuit, overload, overheating), the equipment is automatically turned off and the backup version is connected.
Cabinets Wilo SK
Wilo SK-712, SK-FC, SK-FFS ranges are designed to control several pumps - from 1 to 6 units.
Several automatic circuits in the Wilo SK-712 cabinet greatly simplify the operation of pumping stations
Specifications:
- Voltage –380 V, 50 Hz
- Engine power of connected equipment - from 0.37 to 450 kW
- Temperature range - from + 1 ° С to +40 ° С
- Degree of protection: IP54
During operation, all technological parameters are displayed. In the event of an emergency, an error code is displayed.
You can learn more about how the pump control cabinets function from the following videos.
How to make the simplest SHUN with your own hands:
An example of a typical SHUN at a test bench:
The use of pump control cabinets makes it possible to efficiently use the resources of downhole or drainage equipment and save energy. Knowing the technical characteristics of your pumping station, you can purchase the basic SHUN model or make an order according to an individual scheme.
Do you want to share your own experience, tell us how you assembled, installed and connected the pump control cabinet? Do you have interesting information or questions that arose during the review of the information we proposed? Please write comments.